SVI #774 Page 107 of 126 April 19, 2010
SCBA FILL ENCLOSURE AND ACCESS DOOR CONTROL
The fill station must allow the complete fill process to be accomplished from the front and include an access door control
that enhances the enclosure containment design, is simple to operate and requires minimal physical operator effort. Two
(2) fill whips, each fitted with a cylinder fill adapter, shut-off valve and pressure bleed valve shall be located within the
enclosure.
The access door assembly shall include two (2) integral, steel cylinder sleeves to secure the SCBA cylinders while being
filled. The assembly shall include a handle permitting the operator to slide the access door clear of the enclosure frame
and swing-out the cylinder sleeves towards the operator for loading and unloading cylinders with minimal effort.
The access door shall be supported on the enclosure frame with an adjustable bearing bushing on each side assuring a
balanced and smooth rotation when opening and closing.
SCBA CYLINDER FILL ENCLOSURE FLOW CONTROL SYSTEM (SIDE MOUNT)
The SCBA cylinder fill control system shall include an air control panel with all components, devices and piping
arrangement necessary to direct compressed high pressure breathing air to the SCBA cylinders being filled. (A)
The SCBA cylinder fill control system shall include a regulated air control panel with all components, devices and piping
arrangement necessary to direct supplied compressed high pressure breathing air to the SCBA cylinders being filled.
Additionally, an inlet CGA connection and flow valve shall be provided to direct high pressure breathing air from an
external source to the air storage system. (B)
A cascade control system shall be included for the number of banks specified below. The cascade control system shall
permit drawing down each air storage cylinder, independently of each other, while filling SCBA cylinders (C)
All air flow components and indicators must be labeled and mounted on a steel control panel located above the fill
enclosure. (A, B, C)
The panel shall be painted in a matte shade with a textured finish to eliminate glare and enhance the visibility of gauges
and indicators. The control panel shall be illuminated. The panel shall be designed so that it can slide forward, out of the
compartment, and tipped down so that all piping and components are accessible for maintenance.
As a minimum, the air control panel must include the following:
1. Inlet pressure gauge. (A)
2. SCBA/SCUBA cylinder(s) fill control valve. (A)
3. SCBA/SCUBA cylinder(s) fill pressure gauge. (A)
4. Panel lights on/off switch. (A)
5. Adjustable, 0-6000 PSI self-relieving regulator. (B)
6. Regulator outlet pressure gauge. (B)
7. Air storage fill, CGA inlet fitting and flow control valve. (B)
8. Four (4) bank cascade control with a single valve and gauge per bank. (C)
The Sidewinder X2 fill station with 4-bottle cascade air controls will be approximately 33" wide x 25" high x 23" deep and
weight 700 pounds.
STEP / GROUND LIGHTS
Step and ground lights shall be OnScene Solutions 9" LED Nightstik and be placed at any entry door and step where
personnel climb on or descend from the apparatus to ground level. OnScene LED lights shall have 6 LED lights per 9”
light, and shall be rated at 100,000 hours of service. On Scene Solutions LED lights shall be have a 5 year free
replacement warranty.
All of the required step and ground lights shall be activated when the parking brake is set.