BENDIX BW2000 Bedienungsanleitung Seite 33

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 36
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 32
33
IMPORTANT!
Do not use Grease containing molyb-
denum disulphate. Use only Bendix
Actuators recommended
by the Vehicle Manufacturer.
12 Actuation cylinder replacement
(for Axial- and Radial Disc Brake)
Before fitting the new Brake Actuator, the sealing
surface of the Caliper (see arrow) must be cleaned, and
the Spherical Cup (19) in the Lever must be greased
with white Grease RENOLIT HLT2 (Order no II14525).
The surface area of the flange must be clean.
Attach Actuator with new Nuts
(self-locking EN ISO 7042) and torque tighten
to 133
+22
ft. lbs. (180
+30
Nm).
Connect the air hose and check for leakage.
Make sure that the hose is not twisted and that chafing
is not possible.
IMPORTANT!
Test any air hoses or fittings removed
during maintenance work, using a soap
18/2
VF 00127/10
19
M+P-KN-034-Äi01
12.1 Brake Chamber removal
Disconnect the air line from the Brake Chamber (18/2)
Unscrew the Brake Chamber Mounting Nuts (do not
re-use them).
Remove the Brake Chamber
12.2 Brake Chamber fitting
IMPORTANT:
New Brake Chambers (18/2) have drain plugs instal-
led. Remove the bottom plug (see arrows). All other drain
holes should be plugged.
Road test vehicle before returning to service.
solution to check for leakage. A 1 inch
bubble in 1 minute is acceptable, otherwise
repair/replace components as necessary.