35
MBS-2 Installation
Figure 23, Clearing Stored Fault Codes
Clearing Stored Fault Codes
Turn all power OFF
Power the stop lamp circuit (red).
Malfunction lamp will light
and then turn OFF
NOTE: Power with a light
tester or by pulling down
on the trailer brake lever.
Does the malfunction lamp turn
OFF and remain OFF?
No other stored faults exist
Other stored faults exist.
The malfunction lamp will flash the
next stored fault code then turn OFF,
then repeat the flash sequence for
one minute
Power the auxiliary circuit (blue):
• One second ON
• One second OFF
• One second ON
• One second OFF
• One second ON
• One second OFF
• ON
The malfunction lamp will flash
rapidly (even if no fault is present).
NOTE: Power with a light
tester or by turning the
ignition ON and OFF
(newer models).
YES NO
Repeat
Procedure
281UX020